As part of the *Buy America Build America* program, this XeteX Basis of Design replacement project highlights one of 14 custom air handling units (AHUs) for an international airport renovation. It features an all-aluminum construction with a highly corrosion resistant design.

## Performance

Model: XAH-16000-RT-RC-CW-HW-FF  
Dimensions: 90”H x 251”L x 128”W  
Weight: 9,385 lbs  
Supply CFM: 15,785 CFM  
Heating Type: Hot Water Coil  
Heating Capacity: 444 MBH  
Cooling Type: Chilled Water Coil  
Cooling Capacity: 690 MBH

## Construction

- Outdoor unit with **thermal break construction**
- 4” double wall casing with injected foam (R-value 28) insulation 
    - 0.063” **aluminum exterior casing** with acrylic paint
    - 0.050” **aluminum interior casing**
- 6” welded **structural aluminum base frame** with acrylic paint and **lining along bottom**
- **Aluminum 0.063 floor** with 2” injected foam (R-value 14) insulation
- **2” upturn lip aluminum tread plate floor**

## Features

- **Full unit controls**
- **Threaded rigid aluminum conduit throughout entire unit**
- **NEMA 4x junction boxes suitable for wash down pressure washer construction**
- **Six zone SA damper**
- **A secondary gasket and third door handle added to enhance leakage resistance, reduce airflow escaping, and minimize contaminants within unit to deliver improved air quality**
- Plumbing and electrical chase
- SA/EA PIEZO flow rings

## Components

A. OA 2” MERV with aluminum rack  
B. SA 4” MERV 16 with aluminum rack  
C.  SA premium two plenum fans with TEWD enclosure  
D. Epoxy coated chilled water coils with stainless steel casing and coil rack  
E. Epoxy coated hot water coils with stainless steel casing   
F. EA premium plenum fan with TEWD enclosure  
G. SA multizone damper

## Learn more about XeteX custom Air Handling Units

<https://xetex.com/hs/cta/wi/redirect?encryptedPayload=AVxigLJEnDwZP7elY4qZGPIYqCH7rlR1wm0KoG2yoOgMKEyM54d7ek4Y0k9Db8PdMBjqGqZcbrlkZWejT8vmXWL%2FE9Gi1ZgHNhtvBt12YyGySMuwZdnBeU4JsmCD9uzJhx9QEMlZF0vzkrtz8mbyKyUxJzYrY3yokQp0yRztdahDuhdI5CC9S4Ui%2BamvIydULopCp0aw&webInteractiveContentId=182218501548&portalId=22651078>

[View full post](https://xetex.com/blog/custom-air-handling-replacement-units-with-ultra-corrosion-resistant-design)

```json
{
  "@context" : "http://schema.org",
  "@type" : "BlogPosting",
  "author" : {
    "@type" : "Person",
    "name" : "XeteX"
  },
  "dateModified" : "2025-08-20T13:00:01.511Z",
  "datePublished" : "2025-08-20T13:00:00Z",
  "headline" : "Custom Air Handling Replacement Units with Ultra Corrosion Resistant Design",
  "image" : {
    "@type" : "ImageObject",
    "height" : 337,
    "url" : "https://22651078.fs1.hubspotusercontent-na2.net/hubfs/22651078/XeteX%20Blog%20features/Replacent-units-for-an-airport.jpg",
    "width" : 800
  },
  "mainEntityOfPage" : "https://xetex.com/blog/custom-air-handling-replacement-units-with-ultra-corrosion-resistant-design",
  "publisher" : {
    "@type" : "Organization",
    "logo" : {
      "@type" : "ImageObject",
      "height" : 60.0,
      "url" : "https://22651078.fs1.hubspotusercontent-na1.net/hubfs/22651078/XeteX%20logo/XeteX%20with%20tag%20250px.png",
      "width" : 178.57143
    },
    "name" : "XeteX Air Handling Blog"
  }
}
```