title: Semi Custom ERV with 80% Energy Effectiveness for a University
description: Designed for a university, this AVENTUS semi-custom ERV features an 8” energy wheel with VFD and rotation detector providing 80% energy effectiveness.
---

[XeteX Air Handling Blog ](https://xetex.com/blog)

# [Semi Custom ERV with 80% Energy Effectiveness for a University](https://xetex.com/blog/semi-custom-erv-with-80-energy-effectiveness-for-a-university)

 Written by [XeteX](https://xetex.com/blog/author/xetex) | 1/5/26 4:00 PM

This AVENTUS by XeteX project showcases one of two outdoor semi-custom energy recovery ventilators (ERV) for a university. It features an 8” aluminum energy wheel with VFD and rotation detector providing 80% energy effectiveness.

Let's take a look at performance and see what's inside.

## PERFORMANCE

Model: AVT-ED-2200-RT  
Dimensions: 98”H x 122”L x 95”W  
Weight: 4,950 lbs  
Supply CFM:  6,800 CFM  
Energy Recovery: Energy Wheel  
Energy Effectiveness: Winter: 80%/ Summer: 80%

## CONSTRUCTION

- Outdoor unit
- 2” R-12 foam board unit panels, floor and roof 
    - 16ga galvanized metal exterior panel with acrylic paint
    - 20ga galvanized metal interior panel
- Welded 5” structural steel base with lifting lugs
- 2” R-14 injected foam doors with full length stainless steel piano hinge for access to filters, fans and electrical

## FEATURES

- **Full unit controls with BACnet MS/TP and LCD display **
- **Filter pressure gauge**
- **SA/EA EC motors**
- **Field wired GFI service outlet**
- **Fiberglass floor grates in all floor duct openings**

## COMPONENTS

A. SA 2” MERV 8 filters  
B. 8” aluminum energy wheel with VFD and rotation detector  
C. SA fan  
D. RA 2” MERV 8 filters  
E. EA fan

## Learn more about AVENTUS Semi Custom ERVs and DOAS!

<https://xetex.com/hs/cta/wi/redirect?encryptedPayload=AVxigLKpBKFpaYMfL9RzBHjBczmIyFbs4EcU5wBwAT5w0hNjjLhcyjsPy0ED6hG3nv%2Ffmq7vOjNW5dplXvgcxi6ShJ9KeXO7Cb76vdkAz2YuYDBd%2Blb1VE3k8Lz4EL6%2FvtNjUw4THNkF4wQV9cl%2BtIH1jDAZTb9b1YAdZjCaUH0faMma80IP&webInteractiveContentId=186553436478&portalId=22651078>

[View full post](https://xetex.com/blog/semi-custom-erv-with-80-energy-effectiveness-for-a-university)

```json
{
  "@context" : "http://schema.org",
  "@type" : "BlogPosting",
  "author" : {
    "@type" : "Person",
    "name" : "XeteX"
  },
  "dateModified" : "2026-01-05T16:00:01.088Z",
  "datePublished" : "2026-01-05T16:00:01Z",
  "headline" : "Semi Custom ERV with 80% Energy Effectiveness for a University",
  "image" : {
    "@type" : "ImageObject",
    "height" : 337,
    "url" : "https://22651078.fs1.hubspotusercontent-na2.net/hubfs/22651078/XeteX%20Blog%20features/1-7-26-AVENTUS-ERV-for-a-University.jpg",
    "width" : 800
  },
  "mainEntityOfPage" : "https://xetex.com/blog/semi-custom-erv-with-80-energy-effectiveness-for-a-university",
  "publisher" : {
    "@type" : "Organization",
    "logo" : {
      "@type" : "ImageObject",
      "height" : 60.0,
      "url" : "https://22651078.fs1.hubspotusercontent-na1.net/hubfs/22651078/XeteX%20logo/XeteX%20with%20tag%20250px.png",
      "width" : 178.57143
    },
    "name" : "XeteX Air Handling Blog"
  }
}
```